Mold Replacement: Select a suitable mold based on the material hardness to avoid wire breakage due to an insufficient aperture.
Pressure Calibration: Regularly check the hydraulic system pressure (e.g., the nominal pressure of 24MPa in the product specifications) to prevent insufficient stretching due to inadequate pressure.
Lubrication Maintenance: Check the lubricating oil level every 8 hours to prevent accelerated mold wear due to oil line blockage.
Safety Precautions: Wear protective goggles during operation to prevent injury from flying debris when wire breaks; the hydraulic system must be equipped with a pressure overload protection device.